BYCROSS
Atherectomy Catheter
Aspiration Catheter
The Glutton™ Aspiration Catheter is intended for use in the revascularization of patients with acute ischemic stroke secondary to intracranial large vessel occlusive disease (with the internal carotid, middle cerebral–M1 and M2 segments, basilar, and vertebral arteries) within 8 hours of symptom onset. And it is also used for patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV-tpa therapy are candidates for treatment.
Glutton™ Aspiration Catheter is a medical device used to remove blood clots and debris from the blood vessels in the body.
One of its unique features is its hybrid structure of coil and braiding, which combines flexibility and maneuverability. The coil provides flexibility, allowing the catheter to bend and adapt to the shape of the blood vessel, while the braiding adds maneuverability, enabling the catheter to be guided precisely to the location of the blockage.
This hybrid structure allows the catheter to navigate through the narrow and winding blood vessels with ease, ensuring that the clot or debris is removed with minimal trauma to the vessel.
Additionally, the flexibility and maneuverability of the catheter decrease the risk of vessel perforation or damage, which can lead to serious complications.
The hybrid structure of coil and braiding is a significant advancement in the design of aspiration catheters, making them more effective and safer for patients undergoing vascular procedures.
Other unique features is designed with a larger inner-diameter lumen, which ensures a highly efficient aspiration process.
The larger lumen allows a greater volume of fluid or particles to be aspirated quickly, which makes it an ideal tool for medical procedures that require the removal of fluids or foreign objects from the body.
The enhanced aspirating efficiency of the aspiration catheter saves time and reduces the risk of complications associated with prolonged exposure to anesthesia. Moreover, the larger inner-diameter lumen also facilitates easier and smoother insertion of the catheter into the body, minimizing discomfort and trauma to the patient.
Article number | FR Size | Inner Diameter (inch) | Outer Diameter (inch) | Effective Length (cm) |
---|---|---|---|---|
5F-115 | 5F | 0.058 | 0.070 | 115 |
5F-125 | 5F | 0.058 | 0.070 | 125 |
5F-132 | 5F | 0.058 | 0.070 | 132 |
6F-105 | 6F | 0.072 | 0.084 | 105 |
6F-115 | 6F | 0.072 | 0.084 | 115 |
6F-125 | 6F | 0.072 | 0.084 | 125 |
6F-115S | 6F | 0.072 | 0.084 | 115 |
6F-125S | 6F | 0.072 | 0.084 | 125 |
6F-132S | 6F | 0.072 | 0.084 | 132 |